ABTG1824LVTALVTC
Product Category Floor/Ceiling Consoles
Product Range Floor/Ceiling Dual Console range
Capacity 7.10kW Cooling 8.00kW Heating
Model Number ABTG24LVTC
Room Size Medium Room

Technical Specifications

Indoor unit ABTG24LVTC
Outdoor unit AOTG24LATC
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 7.10 (2.9 - 8.0)
Heating Capacity kW (Rated (Min - Max)) 8.00 (2.2 - 9.1)
Input Power Cooling kW (Rated (Max)) 2.14 (2.40)
Input Power Heating kW (Rated (Max)) 2.21 (2.65)
EER Cooling kW/kW 3.32
COP Heating kW/kW 3.61
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.0 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold) 2.5 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 3.863 / 3.564 / 3.599
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.472 / 3.827 / 3.237
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.086 / 4.040 / 4.246
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.478 / 4.099 / 3.470
Running Current amps (Cooling / Heating) 9.0 / 9.3
Moisture Removal l/hr 2.7
Indoor Sound Pressure Cooling dBA (High / Quiet) 49 / 36
Indoor Sound Pressure Heating dBA (High / Quiet) 49 / 36
Outdoor Sound Pressure dBA (Cooling / Heating) 53 / 54
Outdoor Sound Power dBA 68
Air Circulation (Indoor - High Fan) Cooling l/sec 272
Air Circulation (Indoor - High Fan) Heating l/sec 272
Indoor Unit Dimensions mm (Height x Width x Depth) 199 x 990 x 655
Indoor Unit Weight kg 27.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 830 x 900 x 330
Outdoor Unit Weight kg 60.00
Piping Connects mm Ø (Liquid / Gas) 6.35 / 15.88
Pipe Length m (Max (Precharged)) 30 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 2,100

Dimensions

What’s included in your purchase

ABTG1824LVTALVTC

ABTG24LVTC

Indoor Unit

AOTG24LATC

Outdoor Unit

AR-RAH2E

Wireless Remote Controller

Optional Parts

UTY-RNNYN

UTY-RNNYN

Wired Remote Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

WHITE BOX

UTY-XWZX

External Connect Kit

Key features

 


  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Double Swing Automatic
    Double Swing Automatic

    Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Removable Intake Grill
    Removable Intake Grill

    The indoor unit’s intake grille can be removed for easy cleaning and maintenance.

  • Right Left Swing
    Right / Left Swing Louvre

    The right/left louvre automatically swings in either direction.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Connect Kit

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial Floor/Ceiling Dual Console range

Back to Residential Floor/Ceiling Dual Console range Back to Commercial Floor/Ceiling Dual Console range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General air conditioner

map-icon-white Find a Stockist