Floor/Ceiling Dual Console
Available in Reverse Cycle - 5.2kW, 7.1kW
Refrigerant R410A

Warranty Information

Download our warranty card to read about our 5 year warranty

View Warranty Info

Key features

  • 10 Degree Heat
    10°C Heat Operation

    The room temperature can be set to go no lower than 10°C, thus ensuring that the room does not get too cold when not occupied.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Shut Louvre
    Auto Shut Louvre

    The auto shut louvres close or open automatically when the unit stops or starts.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Automatic Air Flow Adjustment
    Automatic Air Flow Adjustment

    The micro-processor automatically adjusts the air flow to follow changes in room temperature.

  • Automatic Louvre
    Automatic Louvre

    The position of the louvres is set automatically to match the operating mode. It is also possible to adjust the louvres using the remote control.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Double Swing Automatic
    Double Swing Automatic

    Complex swing action of the louvres enables them to swing automatically in both horizontal and vertical directions.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Mildew Resistant Filter
    Mildew Resistant Filter

    The air filter has been treated to resist mildew growth, thus allowing cleaner use and easier care.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Removable Intake Grill
    Removable Intake Grill

    The indoor unit’s intake grille can be removed for easy cleaning and maintenance.

  • Right Left Swing
    Right / Left Swing Louvre

    The right/left louvre automatically swings in either direction.

  • Sleep Timer
    Sleep Timer

    The micro-processor gradually changes the room temperature, allowing you to sleep comfortably at night.

  • Up Down Swing
    Up/Down Swing Louvre

    The up/down louvre automatically swings up and down.

  • v-PAM
    V-PAM

    v-PAM inverter technology increases the maximum output of the compressor significantly and enables high power and high efficiency.

  • Weekly Setback Timer
    Weekly + Setback Timer

    Weekly + setback timer can set temperature for two time spans and for each day of the week.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Technical Specifications

Attribute ABTG18LVTA 5.20kW(C) 6.00kW(H) View model ABTG24LVTC 7.10kW(C) 8.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
5.20 (0.9 - 5.9) 7.10 (2.9 - 8.0)
Heating Capacity kW (Rated (Min - Max))
6.00 (0.9 - 7.5) 8.00 (2.2 - 9.1)
Input Power Cooling kW (Rated (Max))
1.51 (1.82) 2.14 (2.40)
Input Power Heating kW (Rated (Max))
1.66 (2.35) 2.21 (2.65)
EER Cooling kW/kW
3.44 3.32
COP Heating kW/kW
3.61 3.61
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.5 / 2.5 / 2.5 2.0 / 2.0 / 2.0
Star Rating Heating (0-10) (Hot / Average / Cold)
2.5 / 2.0 / 1.5 2.5 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.480 / 4.075 / 4.159 3.863 / 3.564 / 3.599
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.437 / 3.903 / 3.356 4.472 / 3.827 / 3.237
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.807 / 4.827 / 5.117 4.086 / 4.040 / 4.246
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.442 / 4.116 / 3.652 4.478 / 4.099 / 3.470
Running Current amps (Cooling / Heating)
6.4 / 7.0 9.0 / 9.3
Moisture Removal l/hr
2.0 2.7
Indoor Sound Pressure Cooling dBA (High / Quiet)
44 / 32 49 / 36
Indoor Sound Pressure Heating dBA (High / Quiet)
44 / 32 49 / 36
Outdoor Sound Pressure dBA (Cooling / Heating)
55 / 56 53 / 54
Outdoor Sound Power dBA
71 68
Air Circulation (Indoor - High Fan) Cooling l/sec
217 272
Air Circulation (Indoor - High Fan) Heating l/sec
217 272
Indoor Unit Dimensions mm (Height x Width x Depth)
199 x 990 x 655 199 x 990 x 655
Indoor Unit Weight kg
27.00 27.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
620 x 790 x 290 830 x 900 x 330
Outdoor Unit Weight kg
41.00 60.00
Piping Connects mm Ø (Liquid / Gas)
6.35 / 12.7 6.35 / 15.88
Pipe Length m (Max (Precharged))
30 (15) 30 (20)
Max Height Difference m
20 30
Operation Range Cooling °CDB (Min to Max)
-10 to 46 -10 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24
Refrigerant Type
R410A R410A
Refrigerant Amount g
1,650 2,100
Commercial Call To Action

Find a commercial authorised partner

map-icon-white Find a Stockist

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

Oasis Shopping Centre

Oasis Shopping Centre

View Case Study
ESCA / MDLR Pty Ltd

ESCA, Inman Valley, SA

View Case Study
METRO AIR

McDonalds

View Case Study
AUSTRALIAN TURF CLUB

Winx Stand

View Case Study

This product is part of Light Commercial

Back to Light Commercial