Product Category Mid Static Slimline R32 (HP)
Product Range Mid Static Slimline R32 (HP) range
Capacity 8.50kW Cooling 10.00kW Heating
Model Number ARTH30KMTAP-HP

Technical Specifications

Indoor unit ARTH30KMTAP
Outdoor unit AOTH30KCTA
Operation Type Reverse Cycle
Power Source V/Ph/Hz 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max)) 8.50 (4.1 - 10.5)
Heating Capacity kW (Rated (Min - Max)) 10.00 (4.2 - 11.5)
Input Power Cooling kW (Rated (Max)) 2.26 (3.38)
Input Power Heating kW (Rated (Max)) 2.47 (3.12)
EER Cooling kW/kW 3.76
COP Heating kW/kW 4.05
Star Rating Cooling (0-10) (Hot / Average / Cold) 3.5 / 2.5 / 2
Star Rating Heating (0-10) (Hot / Average / Cold) 3 / 3 / 3
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 4.8 / 4.569 / 4.727
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 5.036 / 4.472 / 3.899
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.084 / 5.154 / 5.481
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 5.043 / 4.702 / 4.207
Running Current amps (Cooling / Heating) 9.6 / 10.5
Moisture Removal l/hr 1.6
Indoor Sound Pressure Cooling dBA (High / Quiet) 38 / 28
Indoor Sound Pressure Heating dBA (High / Quiet) 38 / 28
Outdoor Sound Pressure dBA (Cooling / Heating) 51 / 53
Outdoor Sound Power dBA 69
Static Pressure Range PA (Min to Max) 50 to 150
Air Circulation (Indoor - High Fan) Cooling l/sec 541.67
Air Circulation (Indoor - High Fan) Heating l/sec 541.67
Indoor Unit Dimensions mm (Height x Width x Depth) 240 x 1400 x 700
Indoor Unit Weight kg 42.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 998 x 940 x 320
Outdoor Unit Weight kg 64.00
Piping Connects mm Ø (Liquid / Gas) 9.52 / 15.88
Pipe Length m (Max (Precharged)) 75 (30)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -10 to 50
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R32
Refrigerant Amount g 2,100

Dimensions

What’s included in your purchase

ARTH30KMTAP

Indoor Unit

AOTH30KCTA

Outdoor Unit

uty-rnrt

UTY-RNRT

Wired Remote Controller - Backlit Touch Panel Wall Controller

Optional Parts

UTY-ANY1

WiFi Control - anywAiR Technology Ducted Controller

UTY-CDPXZC

Zone Control Interface Module - 8 Zones, 24V

UTY-CDPXZD

Zone Control Interface Module - 8 Zones, 240V

UTY-CDRXZC

ZONE CONTROL INTERFACE MODULE (R32, 8 ZONES, 24V)

UTY-CDRXZD

ZONE CONTROL INTERFACE MODULE (R32, 8 ZONES, 240V)

UTY-LBTYM

Wireless Remote Controller - Wireless Remote Controller & Infra-Red Receiver Kit

UTY-NXT-BOX

WiFi Control

UTY-RHRYT

Wired Remote Controller - Simple Controller Without Mode Button

UTY-RNRYT5

Wired Remote Controller - Backlit Touch Panel Wall Controller

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

UTY-RSRYT

Wired Remote Controller - Simple Controller With Mode Button

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

UTY-RVRY

Wired Remote Controller - KAGAMI Wired Remote Controller

UTY-VTGX Image

UTY-VTGX

Network Converter

UTD-LFDA

UTY-TERX

UTY-VKSX Single Unit KNX Interface

KNX COVERTER INTERFACE

UTY-VMSX Single Unit Modbus Converter

MODBUS Convertor for Indoor Unit

WHITE BOX

UTY-VTGXV

UTY-XCSX

External Input & Output PCB

UTY-XSZX

Remote Temperature Sensor

UTY-XWZXZ3

External Connect Kit

UTY-XWZXZG

External Connection Wire

UTZ-GXDA

Key features

The Fujitsu General Mid Static Slimline R32 (HP) models are designed with a narrow 240mm high chassis and a built-in drain pump, for easy installation in tighter bulkhead and ceiling applications. With a maximum pipe length of 75m, these models are ideal for installation on the roof and in plant rooms in residential apartment buildings.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • In-Built drain pump
    In-Built Drain Pump

    The drain pump is in-built into the system.

  • Automatic Fan Speed Adjustment

    The micro-processor automatically adjusts air flow to follow changes in room temperature

  • Operating Temperature Range 50°C

    The maximum guaranteed operating temperature range to 50 degrees in cooling mode.

  • Demo Mode

    This function allows the indoor unit to be operated alone at exhibitions and showrooms.

  • Long Piping Capability 75m

    This product is equipped with a maximum pipe length of 75m.

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial Mid Static Slimline R32 (HP) range

Back to Residential Mid Static Slimline R32 (HP) range Back to Commercial Mid Static Slimline R32 (HP) range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General air conditioner

map-icon-white Find a Stockist