ARTC72LATU
Product Category High Static Three Phase
Product Range High Static Three Phase range
Capacity 20.30kW Cooling 22.60kW Heating
Model Number ARTC72LATU

Technical Specifications

Indoor unit ARTC72LATU
Outdoor unit AOTA72LALT
Operation Type Reverse Cycle
Power Source V/Ph/Hz 400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max)) 20.30 (10.8 - 23.5)
Heating Capacity kW (Rated (Min - Max)) 22.60 (12.0 - 26.5)
Input Power Cooling kW (Rated (Max)) 6.25 (10.1)
Input Power Heating kW (Rated (Max)) 6.27 (10.1)
EER Cooling kW/kW 3.25
COP Heating kW/kW 3.6
Star Rating Cooling (0-10) (Hot / Average / Cold) 2.0 / 1.5 / 1.5
Star Rating Heating (0-10) (Hot / Average / Cold) 2.0 / 1.5 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) 3.857 / 3.414 / 3.409
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) 3.629 / 3.434 / 3.119
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 4.13 / 4.051 / 4.245
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) 3.614 / 3.486 / 3.233
Running Current amps (Cooling / Heating) 9.3 / 9.3
Moisture Removal l/hr 4.5
Indoor Sound Pressure Cooling dBA (High / Low) 47 / 41
Indoor Sound Pressure Heating dBA (High / Low) 47 / 41
Outdoor Sound Pressure dBA (Cooling / Heating) 57 / 57
Outdoor Sound Power dBA 80
Static Pressure Range PA (Min to Max) 50 to 250
Air Circulation (Indoor - High Fan) Cooling l/sec 1195
Air Circulation (Indoor - High Fan) Heating l/sec 1195
Indoor Unit Dimensions mm (Height x Width x Depth) 450 x 1587 x 700
Indoor Unit Weight kg 100.00
Outdoor Unit Dimensions mm (Height x Width x Depth) 1690 x 930 x 765
Outdoor Unit Weight kg 215.00
Piping Connects mm Ø (Liquid / Gas) 12.7 / 25.4
Pipe Length m (Max (Precharged)) 75 (20)
Max Height Difference m 30
Operation Range Cooling °CDB (Min to Max) -5 to 46
Operation Range Heating °CDB (Min to Max) -15 to 24
Refrigerant Type R410A
Refrigerant Amount g 11,200

Dimensions

What’s included in your purchase

ARTC72LATU

ARTC72LATU

Indoor Unit

AOTA72LALT

AOTA72LALT

Outdoor Unit

UTY-RVNYN

UTY-RVNYN

Wired Remote Controller - Backlit Wired Controller

Optional Parts

UTB-TUD

UTB-TUD

Wired Remote Controller

UTY-ANY1

WiFi Control - anywAiR Technology Ducted Controller

UTY-CDPXZC

Zone Control Interface Module - 8 Zones, 24V

UTY-CDPXZD

Zone Control Interface Module - 8 Zones, 240V

UTY-RSNYN

UTY-RSNYN

Wired Remote Controller - Simple Controller With Mode Button

9708757001

Adapter to connect UTD-RS100

UTD-ECS5A

External Control Wiring Kit

UTD-RS100

Remote Temperature Sensor

UTY-XWZXZ2

External Connect Kit

Key features

Works at an optimum setting to create a comfortable home environment.

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Automatic Fan Speed Adjustment

    The micro-processor automatically adjusts air flow to follow changes in room temperature

Operating Manual

Click on the Download button below to get the pdf

Download PDF

This product is part of the Residential and Commercial High Static Three Phase range

Back to Residential High Static Three Phase range Back to Commercial High Static Three Phase range
Get a Fujitsu Air Conditioner

Get a Quote

Find where to buy a Fujitsu General air conditioner

map-icon-white Find a Stockist