High Static Three Phase
Available in Reverse Cycle - 10.0kW, 12.5kW, 14.0kW, 15.5kW
Refrigerant R32

Download our brochure

Download or view the brochure in a PDF by clicking below

Download PDF

Warranty Information

Download our warranty card to read about our 5 year warranty

View Warranty Info

Key features

  • Zone Control
    Zone Control

    This function enables efficient air-conditioning by selecting specific zones from the various zones divided within the indoor space.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Demand Response

    This product is designed to be compatible with Air Conditioning Demand Response program. When your electricity supplier activates one of the three modes the air conditioner switches over to the appropriate operation.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

  • Operating Temperature Range 50°C

    The maximum guaranteed operating temperature range to 50 degrees in cooling mode.

  • Demo Mode

    This function allows the indoor unit to be operated alone at exhibitions and showrooms.

  • Automatic Static Pressure Setting Adjustment

    With this feature, the unit automatically sets the optimal static pressure setting, eliminating the need for the installer to select and set the static pressure setting each time.

Technical Specifications

Attribute ARTH36KHTA-3PH 10.00kW(C) 11.20kW(H) View model ARTH45KHTA-3PH 12.50kW(C) 14.00kW(H) View model ARTH54KHTA-3PH 14.00kW(C) 15.50kW(H) View model ARTH60KHTA-3PH 15.50kW(C) 18.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
400 / 3 / 50 400 / 3 / 50 400 / 3 / 50 400 / 3 / 50
Cooling Capacity kW (Rated (Min - Max))
10.00 (2.8 - 11.4) 12.50 (4 - 14) 14.00 (4.5 - 15) 15.50 (5 - 16.5)
Heating Capacity kW (Rated (Min - Max))
11.20 (2.7 - 14) 14.00 (4.2 - 16.5) 15.50 (1.7 - 18) 18.00 (5.1 - 19)
Input Power Cooling kW (Rated (Max))
3.08 (4.01) 3.8 (5.16) 4.64 (5.17) 4.94 (6.02)
Input Power Heating kW (Rated (Max))
2.8 (4.21) 3.42 (5.22) 4.4 (5.23) 4.89 (6.74)
EER Cooling kW/kW
3.25 3.29 3.02 3.14
COP Heating kW/kW
4 4.09 3.52 3.68
Star Rating Cooling (0-10) (Hot / Average / Cold)
3 / 2.5 / 3 3 / 2.5 / 3 2.5 / 2.5 / 2.5 2.5 / 2.5 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
3 / 2.5 / 1.5 3 / 2.5 / 2 3 / 2 / 1.5 2.5 / 2 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.642 / 4.426 / 4.675 4.612 / 4.403 / 4.635 4.339 / 4.147 / 4.39 4.378 / 4.193 / 4.416
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.72 / 4.073 / 3.429 4.766 / 4.208 / 3.574 4.691 / 3.937 / 3.306 4.487 / 3.885 / 3.31
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.972 / 5.144 / 5.544 4.928 / 5.083 / 5.465 4.647 / 4.816 / 5.195 4.673 / 4.821 / 5.181
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.72 / 4.34 / 3.67 4.764 / 4.41 / 3.901 4.706 / 4.101 / 3.573 4.491 / 4.135 / 3.523
Running Current amps (Cooling / Heating)
5.2 / 4.7 6.4 / 5.7 7.7 / 7 7.8 / 7.9
Moisture Removal l/hr
1.4 0.9 1.6 2.8
Indoor Sound Pressure Cooling dBA (High / Quiet)
41 / 36 43 / 35 45 / 36 45 / 36
Indoor Sound Pressure Heating dBA (High / Quiet)
41 / 36 43 / 35 45 / 36 45 / 36
Outdoor Sound Pressure dBA (Cooling / Heating)
53 / 53 55 / 57 55 / 57 53 / 55
Outdoor Sound Power dBA
70 71 72 71
Static Pressure Range PA (Min to Max)
60 to 210 60 to 260 60 to 260 60 to 260
Air Circulation (Indoor - High Fan) Cooling l/sec
695 903 986 986
Air Circulation (Indoor - High Fan) Heating l/sec
695 903 986 986
Indoor Unit Dimensions mm (Height x Width x Depth)
400 x 1050 x 500 425 x 1250 x 490 425 x 1250 x 490 425 x 1250 x 490
Indoor Unit Weight kg
39.00 53.00 53.00 53.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
788 x 940 x 320 998 x 940 x 320 998 x 940 x 320 1418 x 970 x 370
Outdoor Unit Weight kg
53.00 67.00 67.00 96.00
Piping Connects mm Ø (Liquid / Gas)
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
50 (30) 50 (30) 50 (30) 50 (30)
Max Height Difference m
30 30 30 30
Operation Range Cooling °CDB (Min to Max)
-10 to 50 -10 to 50 -10 to 50 -10 to 50
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R32 R32 R32 R32
Refrigerant Amount g
1,500 2,180 2,180 3,400
Commercial Call To Action

Find a commercial authorised partner

map-icon-white Find a Stockist

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

Oasis Shopping Centre

Oasis Shopping Centre

View Case Study
ESCA / MDLR Pty Ltd

ESCA, Inman Valley, SA

View Case Study
METRO AIR

McDonalds

View Case Study
AUSTRALIAN TURF CLUB

Winx Stand

View Case Study

This product is part of Light Commercial