High Static Compact Header
Available in Reverse Cycle - 8.5kW, 10.0kW, 11.5kW
Refrigerant R410A

Warranty Information

Download our warranty card to read about our 5 year warranty

View Warranty Info

Key features

  • All DC
    All DC

    With All DC, electricity loss is decreased and power consumption reduced.

  • Auto Changeover
    Auto Changeover

    The unit automatically switches between operating modes based on the temperature setting and room temperature.

  • Auto Restart
    Auto Restart

    Should there be a temporary loss of power, the unit will automatically restart itself in the same operating mode, once the power is restored.

  • Blue Fin Heat Exchanger
    Blue Fin Heat Exchanger

    Corrosion-resistance of the heat exchanger in coastal areas has been improved by blue fin treatment of the outdoor unit heat exchanger.

  • Connectable Distribution Duct
    Connectable Distributing Duct

    Systems are capable of attaching a field-supplied branch ducts distributing the airflow.

  • Connectable Fresh Air Duct
    Connectable Fresh Air Duct

    Allows introduction of fresh air to the occupied space.

  • Economy Mode
    Economy Mode

    Limits the maximum operation current, and performs operation with the power consumption suppressed.

  • Filter Sign
    Filter Sign

    Select appropriate intervals for displaying the filter sign on the indoor unit according to the estimated amount of dust in the air of the room.

  • Fresh Air Intake
    Fresh Air Intake

    Fresh air can be taken in by a fan which can be connected using an external control unit.

  • ON-OFF Timer
    On-Off Timer

    ON-OFF timer can be set to operate once every 24 hours.

  • Program Timer
    Program Timer

    This timer allows selection of one of four options. ON, OFF, ON ––> OFF, or OFF ––> ON.

  • Weekly Timer
    Weekly Timer

    Different ON-OFF times can be set for up to 7 days.

Technical Specifications

Attribute ARTG30LHTAC 8.50kW(C) 10.00kW(H) View model ARTG36LHTAC 10.00kW(C) 12.50kW(H) View model ARTG45LHTAC 11.50kW(C) 14.00kW(H) View model
Operation Type
Reverse Cycle Reverse Cycle Reverse Cycle
Power Source V/Ph/Hz
230 / 1 / 50 230 / 1 / 50 230 / 1 / 50
Cooling Capacity kW (Rated (Min - Max))
8.50 (4.7 - 10.0) 10.00 (5.0 - 11.4) 11.50 (5.7 - 13.5)
Heating Capacity kW (Rated (Min - Max))
10.00 (5.0 - 11.5) 12.50 (5.1 - 14.0) 14.00 (6.0 - 15.5)
Input Power Cooling kW (Rated (Max))
2.61 (4.06) 3.08 (5.04) 3.70 (5.62)
Input Power Heating kW (Rated (Max))
2.70 (4.06) 3.42 (5.04) 3.84 (5.62)
EER Cooling kW/kW
3.26 3.25 3.11
COP Heating kW/kW
3.70 3.65 3.65
Star Rating Cooling (0-10) (Hot / Average / Cold)
2.0 / 2.0 / 2.0 2.5 / 2.0 / 2.0 2.5 / 2.0 / 2.5
Star Rating Heating (0-10) (Hot / Average / Cold)
2.5 / 2.5 / 2.0 3.0 / 2.5 / 1.5 3.0 / 2.0 / 1.5
Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold)
3.922 / 3.663 / 3.731 4.142 / 3.872 / 3.980 4.250 / 3.979 / 4.140
Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold)
4.477 / 4.026 / 3.572 4.617 / 4.044 / 3.478 4.581 / 3.875 / 3.249
Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.149 / 4.141 / 4.371 4.406 / 4.444 / 4.717 4.550 / 4.647 / 4.970
Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold)
4.479 / 4.207 / 3.817 4.625 / 4.278 / 3.791 4.588 / 4.174 / 3.508
Running Current amps (Cooling / Heating)
11.0 / 11.3 13.0 / 14.4 15.5 / 16.1
Moisture Removal l/hr
0.9 1.5 0.9
Indoor Sound Pressure Cooling dBA (High / Low)
41 / 36 41 / 36 43 / 35
Indoor Sound Pressure Heating dBA (High / Low)
41 / 36 41 / 36 43 / 35
Outdoor Sound Pressure dBA (Cooling / Heating)
53 / 55 52 / 54 58 / 58
Outdoor Sound Power dBA
69 68 72
Static Pressure Range PA (Min to Max)
60 to 210 60 to 210 60 to 260
Air Circulation (Indoor - High Fan) Cooling l/sec
695 695 903
Air Circulation (Indoor - High Fan) Heating l/sec
695 695 903
Indoor Unit Dimensions mm (Height x Width x Depth)
400 x 1050 x 500 400 x 1050 x 500 425 x 1250 x 490
Indoor Unit Weight kg
39.00 39.00 54.00
Outdoor Unit Dimensions mm (Height x Width x Depth)
830 x 900 x 330 914 x 970 x 370 914 x 970 x 370
Outdoor Unit Weight kg
61.00 75.00 75.00
Piping Connects mm Ø (Liquid / Gas)
9.52 / 15.88 9.52 / 15.88 9.52 / 15.88
Pipe Length m (Max (Precharged))
50 (20) 50 (20) 50 (20)
Max Height Difference m
30 30 30
Operation Range Cooling °CDB (Min to Max)
-15 to 46 -15 to 46 -15 to 46
Operation Range Heating °CDB (Min to Max)
-15 to 24 -15 to 24 -15 to 24
Refrigerant Type
R410A R410A R410A
Refrigerant Amount g
2,100 2,900 2,900
Commercial Call To Action

Find a commercial authorised partner

map-icon-white Find a Stockist

COMMERCIAL CASE STUDIES

Here are a few examples showcasing Fujitsu General's commercial capabilities.

Oasis Shopping Centre

Oasis Shopping Centre

View Case Study
ESCA / MDLR Pty Ltd

ESCA, Inman Valley, SA

View Case Study
METRO AIR

McDonalds

View Case Study
AUSTRALIAN TURF CLUB

Winx Stand

View Case Study

This product is part of the Light Commercial type